Enhanced Detection of Acute Ischemic Stroke With Low-Field MRI

Read full text
Authors: Annabel Sorby-Adams, Nándor Pintér, Amelia Demopoulos, John E. Kirsch, Vinay Jaikumar, Olivia Nelson, Stephen Bacchi, Jennifer D. Guo, Blair A. Parry, Hailey Brigger, Ian Johnson, A de Havenon
+13 more Gordon Sze, Rafael O’Halloran, John Pitts, Vivien H. Lee, Keith W. Muir, Shahid M. Nimjee, Adnan Siddiqui, Kathryn E. Keenan, Matthew S. Rosen, Juan Eugenio Iglesias, Kevin N. Sheth, Joshua N. Goldstein, W. Taylor Kimberly
Cited by: 4
References: 29

Abstract

BACKGROUND: Portable, low-field magnetic resonance imaging (MRI) has the potential to expand access to neuroimaging in environments where conventional MRI is limited. However, diffusion-weighted imaging at low magnetic field is challenged by a low signal-to-noise ratio and gradient strength, which may limit diagnostic confidence in acute ischemic stroke evaluation, particularly for very small strokes. In this study, we evaluated a combination of novel pulse sequences and low-field MRI hardware to enhance lesion detection. METHODS: Patients with a suspected diagnosis of acute ischemic stroke were prospectively enrolled at 3 centers. Diffusion-weighted imaging was performed using a single-direction (SD) or a custom multi-direction (MD) sequence comprising 3 orthogonal directions. Imaging was acquired on 2 0.064 T hardware versions: a first-generation C-arm system (Swoop v1) and a next-generation H-arm system featuring optimized gradient amplifiers, form factor, and cooling system (Swoop v2). Diagnostic accuracy and the lower limit of lesion detection were calculated for both SD and MD images on each system compared with ground-truth MRI (1.5–3 T). RESULTS: A total of 95 patients (n=62 confirmed acute ischemic stroke; n=33 stroke mimics) were included. On SD images, agreement between assessors regarding lesion detection was κ =0.72, and κ =0.84 on MD images. The positive predictive value for differentiating acute ischemic stroke from stroke mimics was 78.2% on SD and 95% on MD images. For SD images, a lesion volume cut point of 0.6 mL yielded a sensitivity of 89% and specificity of 88%. For MD images, the lesion volume cut point was 0.4 mL, with a corresponding sensitivity of 86% and specificity of 83%. MD imaging on the next-generation v2 system improved image uniformity ( P

Fields of Study & Subjects

Advanced MRI Techniques and Applications Acute Ischemic Stroke Management Advanced Neuroimaging Techniques and Applications

Publication details

Journal / source
Stroke Vascular and Interventional Neurology
Publisher
Ovid Technologies (Wolters Kluwer Health)
Volume
6
Issue
2
Pages
e002110–e002110
Publication date
21 January 2026
Language
EN