A Prospective Multicenter Observational Study Investigating the Concordance Between Patient-Reported Hearing Loss and Commonly Used Ototoxicity Grading Systems in Patients Treated with Platinum-Based Chemotherapy

View at publisher
Authors: Anouk V. M. Burger, Charlotte W. Duinkerken, Eleonoor A. R. Theunissen, Anouk W. M. A. Schaeffers, Michael Hauptmann, Alex E. Hoetink, Alfons J. M. Balm, Jan Paul de Boer, Esther Maas-Bannink, Leonie Exterkate, Marije Slingerland, Jeroen C. Jansen
+7 more Robert Jan Stokroos, Remco de Bree, Lot A. Devriese, Wouter Albert Dreschler, Tjasse Doewe Bruintjes, Klaske E. van Sluis, Charlotte L. Zuur
Cited by: 0
References: 26

Abstract

Purpose: This study aims to compare the accuracy of the TUNE, American Speech-Language-Hearing Association (ASHA), and Common Terminology Criteria for Adverse Events (CTCAE) grading systems in reflecting the severity of treatment-related hearing loss, as measured by pure-tone audiometry and patient-reported hearing loss using the Speech, Spatial, and Qualities of Hearing scale compare questionnaire (SSQ). Methods: This study is a prospective, multicenter, cross-sectional, and observational study from 2018 to 2024 conducted at the Netherlands Cancer Institute - Antoni van Leeuwenhoek Amsterdam, Leiden University Medical Center, and University Medical Center Utrecht. In this trial, 109 patients with an indication for curative platinum-based chemotherapy (dose ≥ 200 mg/m 2 ) were included, of whom 74 were eligible for analysis. Standard frequency and extended high-frequency pure tone audiometry were measured at baseline and follow-up. The SSQ was administered at follow-up to assess patient-reported outcome measures for hearing loss. The TUNE, ASHA, and CTCAE criteria were derived from audiometry. Concordance and Spearman’s correlations were evaluated between all 3 grading systems and the SSQ. Results: The concordance of TUNE with the SSQ was 81%. The concordance of CTCAE and ASHA with the SSQ was 73% and 68%, respectively. A statistically significant Spearman’s correlation coefficient of −.35 ( P = .01) was found between TUNE and the SSQ. The Spearman’s correlation coefficient with CTCAE or ASHA and SSQ was −.10 ( P = .10) and .04 ( P = .75), respectively. Conclusion: This study found that the TUNE is better in reflecting platinum-related patient-reported hearing loss compared to the CTCAE and ASHA.

Fields of Study & Subjects

Hearing Cochlea Tinnitus Genetics Hearing Loss and Rehabilitation Cancer Treatment and Pharmacology

Publication details

Journal / source
Annals of Otology Rhinology & Laryngology
Volume
135
Issue
6
Pages
443–452
Publication date
18 January 2026
Language
EN