A Krackow-based suture technique as a novel alternative for feline patellar fracture repair: a biomechanical comparison
Abstract
Objectives The aim of the study was to evaluate the biomechanical properties of the combination of circumferential and Krackow sutures using FiberWire compared with the conventional methods in feline transverse patellar fractures. Methods A total of 24 feline cadaveric pelvic limbs (mean body weight 3.74 kg) were harvested, and the patella of each limb was osteotomised transversely to simulate a fracture. The limbs were then randomly assigned to 1/3 stabilisation methods (n = 8 per group): group 1 (PFW) was stabilised with a modified tension band wire with a 0.9 mm Kirschner wire and No 2 FiberWire; group 2 (CFS) was stabilised with a circumferential and figure-of-eight suture with No 2 FiberWire; and group 3 (CKS) was stabilised with a circumferential and Krackow suture with No 2 FiberWire. All knee joints were fixed at a 135° neutral standing angle and tested by applying tensile force. Loads at 1, 2 and 3 mm gap formation, the maximum failure load and failure modes were recorded. Results At 1 mm displacement, group 3 (mean tension 96.1 ± 18.6 N) was significantly stronger than group 1 ( P
Fields of Study & Subjects
Veterinary Orthopedics and Neurology
Bone fractures and treatments
Veterinary Medicine and Surgery
Publication details
- Journal / source
- Journal of Feline Medicine and Surgery
- Volume
- 28
- Issue
- 3
- Pages
- 1098612X261424298–1098612X261424298
- Publication date
- 5 February 2026
- Language
- EN