Corneal densitometry and its association with cumulative dissipated energy after phacoemulsification

Read full text
Authors: Utku Furuncuoğlu, Isıl Uslubas, Müge Toprak
Cited by: 0
References: 26

Abstract

BACKGROUND: To evaluate corneal densitometry after cataract surgery and its association with cumulative dissipated energy (CDE). METHODS: Ninety-nine eyes of 74 patients who underwent uncomplicated phacoemulsification with intraocular lens (IOL) implantation surgery were included in this retrospective study. Examinations were conducted at baseline and 1 and 3 months after phacoemulsification. Corneal densitometry (CD) and 10-mm corneal volume (CV) measurements were obtained from corneal topography (Pentacam, Oculus, Wetzlar, Germany). RESULTS: The mean CV values increased significantly at the 1 and 3 months after surgery compared to baseline value (p

Fields of Study & Subjects

Intraocular Surgery and Lenses Corneal surgery and disorders Drug-Induced Ocular Toxicity

Publication details

Journal / source
BMC Ophthalmology
Volume
26
Issue
1
Publication date
12 March 2026
Language
EN