Endoscope-guided nasoenteric feeding improves sleep quality in ICU patients: a retrospective study

Read full text Summarise with VIRAT
Authors: Yueming Wu, Shangxia Jiang, Liuhua Pan, Jing Zhao, Yihao Kang, Yuequn Chen
Cited by: 0
References: 30

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Poor sleep and circadian disruption are pervasive in critically ill adults receiving enteral nutrition. Whether feeding-tube placement technique influences these physiological outcomes is unknown. Disposable endoscope-guided tubes provide real-time visualization and might improve both procedural performance and downstream sleep–circadian biology. In this single-centre retrospective cohort study, we analysed 32 adults requiring nasoenteric feeding, 16 managed with a disposable endoscopic visual tube and 16 with conventional blind tubes. Baseline demographic, clinical, nutritional, and laboratory characteristics were comparable. The primary endpoint was first-attempt catheterization success confirmed by radiography. Secondary endpoints included overall success, catheterization time, operator ratings, 48-h safety, polysomnography- and actigraphy-derived sleep metrics, and circadian markers (including dim-light melatonin onset [DLMO], relative amplitude, and interdaily stability). Endoscopic guidance improved first-attempt success (15/16 [93.8%] vs. 10/16 [62.5%]; p = 0.03) and shortened catheterization time (6.2 ± 1.3 vs. 8.5 ± 2.1 min; p = 0.004). Operators rated intubation smoother (4.6 ± 0.5 vs. 3.9 ± 0.7; p = 0.002) and more convenient (4.7 ± 0.5 vs. 4.0 ± 0.6; p = 0.003). Vital signs, haemoglobin, creatinine, adverse events, and device defects did not differ significantly ( p > 0.05). Sleep–circadian outcomes showed higher sleep efficiency (82.0 ± 6.7% vs. 69.0 ± 9.7%), shorter sleep latency (12.8 ± 8.6 vs. 30.0 ± 15.8 min), fewer awakenings (5.2 ± 1.6 vs. 10.3 ± 3.6)/arousals (12.8 ± 3.2 vs. 20.0 ± 4.1 events per hour), higher per cent of N3 sleep (18.2 ± 4.0% vs. 10.9 ± 4.8%) and REM sleep (29.7 ± 4.8% vs. 15.8 ± 6.5%), higher RCSQ scores (71.0 ± 8.2 vs. 43.7 ± 12.7 mm), and more favourable circadian markers (including DLMO (19.3 ± 0.9 vs. 21.6 ± 1.0 h), relative amplitude (0.8 ± 0.1 vs. 0.5 ± 0.1), interdaily stability (0.7 ± 0.1 vs. 0.4 ± 0.1, p < 0.001), and intradaily variability (0.8 ± 0.2 vs.1.3 ± 0.3) in the endoscope-guided group (all p < 0.05). Disposable endoscope-guided nasoenteric tube placement was associated with higher first-attempt success and shorter placement time compared with blind placement; compared with blind placement, endoscopic guidance showed directionally favourable sleep efficiency and circadian rhythmicity across complementary endpoints (nominal two-sided p -values).

Fields of Study & Subjects

Clinical Nutrition and Gastroenterology Intensive Care Unit Cognitive Disorders Central Venous Catheters and Hemodialysis

Publication details

Journal / source
European journal of medical research
Volume
31
Issue
1
Pages
936
Publication date
2 April 2026
Language
EN