Safety and performance results from PATHFINDER 2, a registrational study of a multi-cancer early detection (MCED) test in an intended-use population.

View at publisher
Authors: Karthik Giridhar, Charles H. McDonnell, Dax Kurbegov, Marc Ryan Matrana, Shirish M. Gadgeel, Raymond Kim, Gretchen Stipec, Kevin C. Oeffinger, Michael J. Demeure, James W. Lillard, Rebecca Davidson Kaltman, Jennifer Tran
+8 more Alan Roth, SAMI TAHHAN, Andrew Stewart Poklepovic, Donald A. Richards, Rita Lopatin, Celine Marquez, Margaret Elizabeth McCusker, Nima Nabavizadeh
Cited by: 1

Abstract

LBA10509 Background: The MCED test (Galleri) detects a shared cancer signal from cell-free DNA in blood and predicts a cancer signal origin (CSO) to guide diagnostic (dx) workup. PF2 (NCT05155605) is a large, prospective, multicenter, interventional study of the MCED test’s performance and safety in a diverse US intended-use population. Methods: PF2 enrolled participants aged ≥50y without clinical suspicion of cancer or cancer diagnosis/treatment within 3y of enrollment. Primary objectives were MCED performance and safety in terms of dx testing triggered by a positive (cancer signal detected) MCED test result. Participants with a positive MCED test underwent targeted dx workup guided by the predicted CSO(s). Participant-reported anxiety was assessed with the State Trait Anxiety Inventory. Results: PF2 enrolled 35,878 participants; 32,007 with a 12m cancer assessment were analyzable for performance. Of 287 (0.9%) with a positive MCED test, 173 were diagnosed with cancer within 12m, for a cancer detection rate of 0.5% (95% CI 0.5-0.6%) and positive predictive value of 60.3% (54.5-65.8%). Specificity was 99.6% (99.6-99.7%). 12m episode sensitivity was 69.8% (62.8-76.0%) in a prespecified subgroup of 12 cancers responsible for ⅔ of US cancer deaths, 66.2% (55.1-75.8%) in a subgroup of 6 aggressive cancers with low 5y survival, and 39.3% (34.9-44.0%) across all cancers. Overall CSO prediction accuracy was 91.3% (86.2-94.7%) across all cancers. The MCED test detected 151 new primary and 22 recurrent cancers; additional cancers detected by screening were those with USPSTF A/B (n=31) and C (n=60) recommended screening. Of 151 MCED-detected new primaries, 80 (53.0%) were clinical stage I-II; 107 (70.9%) were stage I-III. Of 80 MCED-detected stage I-II cancers, 71.2% had no USPSTF A/B screening recommendation. Of 35,335 participants analyzable for safety, 213 (0.6%) had invasive procedure(s) to evaluate a positive MCED test result, of which 90% were nonsurgical and 1.8x more likely for participants with vs without cancer diagnosis. Most (87.6%) had a CSO-guided dx evaluation. There were 5 study-related adverse events during the time of dx workup; none were serious. Anxiety temporarily increased for participants with a positive MCED test and cancer diagnosed, and returned to baseline by 12m. Of participants with a positive MCED test, median time from test result to dx resolution was 48d (95% CI 43-56). Few participants (7/63 [11.1%]) had cancer found by dx PET/CT after a targeted dx workup that did not reveal cancer. Conclusion: The MCED test demonstrated robust performance with a favorable safety profile. When MCED testing was added to USPSTF A/B screening, 6.5x more cancers were detected by screening, most at early stages. The diverse, representative PF2 participant population supports the generalizability of these findings to the US intended-use population. Clinical trial information: NCT05155605 .

Fields of Study & Subjects

Global Cancer Incidence and Screening Cancer Genomics and Diagnostics BRCA gene mutations in cancer

Publication details

Journal / source
Journal of Clinical Oncology
Publisher
American Society of Clinical Oncology (ASCO)
Volume
44
Issue
17_suppl
Publication date
3 June 2026
Language