Quality Management in Brachytherapy

View at publisher Summarise with VIRAT
Authors: Susan Richardson, K Kielar, Cheng B. Saw, Ali S. Meigooni
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

The International Committee on Radiation Protection (ICRP) Publication 97, entitled “Prevention of High-Dose-Rate Brachytherapy Accidents,” states that as of 2004, there were over 500 reported high-dose-rate (HDR) brachytherapy incidents, including one fatality ( ICRP 2005 ). More recently, Thomadsen et al. reviewed quality and safety guidelines and indicated a medical event rate of 0.02% for HDR treatments in 2009 and 2010 ( Thomadsen et al. 2014 ). Richardson also found that after a review of U.S. Nuclear Regulatory Commission (NRC) events, most mistakes were human error ( Richardson 2012 ). Prevention and mitigation of errors are a result of a good quality management (QM) program. The purpose of the report from the American Association of Physicists in Medicine (AAPM) Task Group 100, “Application of Risk Analysis Methods to Radiation Therapy Quality Management,” is to lend guidance to individuals involved in establishing a QM program for radiation therapy treatments ( Huq et al. 2016 ). This report provides the methodology of failure mode and effects analysis (FMEA) to proactively delineate the incidents that, if they occurred undetected, would be the most probable to happen and the most detrimental to the patient. It additionally describes fault tree analysis (FTA) and the development of risk-informed design for QM programs. Historically, one difficulty for radiation therapy administrators has been to produce an appropriate balance of resources with maximal quality and safety for patients. This method allows concentration of quality assurance (QA) efforts on those events with the greatest need for quality control (QC). Additionally, the publication “Safety is No Accident,” published by the American Society for Therapeutic Radiation Oncology ( ASTRO 2012 ), describes expectations of practice to create a culture of safety within a department. The publication is also endorsed by the AAPM and other radiological societies. It also describes appropriate staffing levels and roles for the radiation oncology team. This chapter seeks to describe the foundational elements of a QM program and provide three case studies of FMEA applied to modern-day brachytherapy treatments, including HDR brachytherapy, low-dose-rate (LDR) prostate implants, and Xoft electronic brachytherapy.

Fields of Study & Subjects

Advanced Radiotherapy Techniques Quality and Safety in Healthcare Patient Safety and Medication Errors

Publication details

Journal / source
CRC Press eBooks
Pages
441–452
Publication date
1 April 2026
Language
EN
Document type
Book chapter