Strengthening of unreinforced masonry walls using ECC for impact/blast resistance
Abstract
This paper presents the results of quasi-static and low-velocity projectile impact tests on unrein-forced masonry (URM) walls retrofitted with a cementitious-based material known as Engineered Cementitious Composite (ECC). A total of 18 masonry wall panels were tested to assess the extent to which ECC can enhance the impact/blast resistance of the strengthened masonry walls by subjecting these series of panels to three types of load patterns namely patch load, uniformly-distributed load and impact load. Test results reported in this paper demonstrate the efficiency of the ECC-strengthening system in improving the ductility of URM walls, increasing their ultimate load-carrying capacity, enhancing their resistance against multiple low-velocity impacts and preventing sudden and therefore catastrophic failure.
Fields of Study & Subjects
Masonry and Concrete Structural Analysis
Structural Response to Dynamic Loads
High-Velocity Impact and Material Behavior
Publication details
- Journal / source
- CRC Press eBooks
- Pages
- 1631–1638
- Publication date
- 4 February 2026
- Language
- EN
- Document type
- Book chapter