Pull-out capacity of screwed connections in steel cladding systems

View at publisher
Authors: M. Mahendran, R. B. Tang
Cited by: 0

Abstract

An investigation was carried out to study the local failure which occurs when a screw fastener pulls out of steel battens, purlins or girts in steel cladding systems. Both two- span cladding tests and small scale tests were conducted. In order to model the pull-out behaviour of steel cladding systems more accurately, an improved design formula was developed in terms of thickness, ultimate tensile strength of steel, thread diameter and pitch of screw. This paper presents the details of this experimental investigation and its results.

Fields of Study & Subjects

Structural Load-Bearing Analysis Construction Engineering and Safety Engineering Structural Analysis Methods

Publication details

Journal / source
CRC Press eBooks
Pages
609–616
Publication date
26 February 2026
Language
EN
Document type
Book chapter