Seismic isolation structure for pool-type LMFBR — Isolation building with vertically isolated floor for NSSS

View at publisher
Authors: A. Sakurai, H. Shiojiri, S. Aoyagi, T. Matsuda, S. Fujimoto, Y. Sasaki, H. Hirayama
Cited by: 0

Abstract

In the design of nuclear power plants, a critical issue is the determination of loadings and response due to earthquakes. A key principle in structural developments of nuclear power plants is the need to maintain elastic behavior during earthquake. Therefore, usual aseismic design requires stiffened structural design for equipments as well as buildings in order to avoid excessive response to seismic waves and to maintain elasticity.

Fields of Study & Subjects

Seismic Performance and Analysis Vibration Control and Rheological Fluids Geotechnical Engineering and Underground Structures

Publication details

Journal / source
CRC Press eBooks
Pages
743–748
Publication date
14 January 2026
Language
EN
Document type
Book chapter