Abstract
It is shown that idealized, lumped-mass models of primary structures may lead to significant overestimation of the peaks in floor response spectra used for design of equipment and piping in nuclear power plants. In real structures, due to the effect of local modes the vibratory energy is dispersed in a band of frequencies around each mode, which reduces the effect of resonance in the equipment response. This effect is investigated in this paper by way of a numerical example and parametric study. It is shown that refined modeling of primary structures may lead to significant reduction in the peaks of floor response spectra.
Fields of Study & Subjects
Seismic Performance and Analysis
Structural Engineering and Vibration Analysis
Vibration and Dynamic Analysis
Publication details
- Journal / source
- CRC Press eBooks
- Pages
- 1087–1092
- Publication date
- 14 January 2026
- Language
- EN
- Document type
- Book chapter