Use of a Tracheal Tube, Flexible Bronchoscope, and a Supraglottic Airway to Remove Foreign Bodies: A Case Report

View at publisher
Authors: Taiki Saito, Ichiro Takenaka, Kazuyoshi Aoyama
Cited by: 0
References: 7

Abstract

When removing an airway foreign body using a flexible bronchoscope through a supraglottic airway device, the foreign body must be passed through the glottis. However, passing the foreign body through the glottis may be difficult because of a relatively narrow glottic opening. We report 2 cases in which a tracheal tube was used to assist bronchoscopic removal of the foreign body when passage through the glottis was difficult. Both foreign bodies were successfully removed without complications. Our method prevented the foreign bodies from being dropped or crushed and was useful as an adjunct to bronchoscopic removal with supraglottic airway devices.

Fields of Study & Subjects

Foreign Body Medical Cases Airway Management and Intubation Techniques Trauma Management and Diagnosis

Publication details

Journal / source
A&A Practice
Volume
20
Issue
1
Pages
e02135–e02135
Publication date
1 January 2026
Language