INTRODUCTION: Kyphoplasty has evolved as a minimally invasive surgical technique for the treatment of vertebral compression fractures (VCFs), offering pain relief and spinal stabilization. The use of titanium microspheres in kyphoplasty has been proposed to provide a more durable augmentation material with potential benefits over traditional polymethylmethacrylate (PMMA). METHODS: A retrospective analysis was conducted on 43 patients (mean age: 56.4 ± 17.6 years) treated with titanium microsphere kyphoplasty between January 2022 and October 2024. Clinical parameters included pain (NRS), disability (ODI), and quality of life (SF-36). Radiological evaluation involved vertebral body height (VBH), wedge angle (WA), and kyphosis angle (KA). All patients underwent spine X-ray, CT, and MRI. Statistical analysis was performed using RStudio. RESULTS: Pain scores significantly improved from 7.63 ± 2.71 preoperatively to 3.67 ± 3.04 at 12 months (p < 0.001). ODI improved from 53.8% to 25.3% (p < 0.001), and SF-36 showed significant gains in physical function and pain domains. Radiologically, KA decreased from 9.61° to 7.87° (p = 0.047), and WA from 9.95° to 5.24° (p < 0.001). Anterior VBH increased significantly (p = 0.011), mid VBH even more so (p < 0.001), while posterior VBH remained stable. No significant changes were observed in cranial or caudal VBH. There were no cases of microsphere leakage or migration; two major complications were reported requiring further surgical intervention. CONCLUSIONS: Kyphoplasty with titanium microspheres appears to be a safe and effective treatment for VCFs, providing substantial clinical and radiological improvements. Titanium may offer a promising alternative to PMMA. Prospective studies are recommended.

Fields of Study & Subjects

Spinal Fractures and Fixation Techniques Management of metastatic bone disease Scoliosis diagnosis and treatment

Publication details

Journal / source
Neurosurgery
Volume
72
Issue
Supplement_1
Pages
177–177
Publication date
26 March 2026