1052 Intraprocedural Rupture During Endovascular Treatment of Unruptured Intracranial Aneurysms: Incidence, Flow-Arrest Dynamics, and Management From a 12-Year Single-Center Experience

View at publisher Summarise with VIRAT
Authors: Mustafa Ismail, Zachary Hubbard, Ariana Alejandra Chacón-Aponte, Timothy Webb, Alejandro M. Spiotta
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

INTRODUCTION: Intraprocedural rupture (IPR) during endovascular treatment of unruptured intracranial aneurysms is infrequent yet potentially devastating. The speed with which blood flow is arrested and final hemostasis achieved—and its interaction with peri-rupture hemodynamics—remains poorly defined. METHODS: We retrospectively reviewed every aneurysm embolization undertaken at the Medical University of South Carolina between 1 January 2013 and 31 December 2024. IPR was defined as angiographic contrast extravasation or device perforation in a previously unruptured saccular aneurysm. For each event, we extracted (1) the interval from the first extravasation frame to complete flow arrest, (2) the duration of flow arrest until reperfusion, and (3) the time from rupture recognition to angiographic hemostasis, all recorded in minutes. Continuous anesthesia traces provided baseline and post-rupture maximum and minimum SBP, MAP, and heart rate; the amplitude of each excursion (Δ) was calculated as post-rupture maximum minus post-rupture minimum. Univariable linear regression related these variables to the mRS at hospital discharge. RESULTS: Among 2565 procedures, 1738 treated unruptured aneurysms; 14 (0.8 %) suffered IPR. The median time to flow arrest was 0.9 min (inter-quartile range 0.4–1.8), with a flow-arrest duration of 8.1 min (4.7–12.6) and a time to hemostasis of 7.3 min (3.2–12.9). Mean ΔSBP and ΔMAP were 40 ± 27 mm Hg and 41 ± 33 mm Hg, respectively. Immediate complete occlusion (Raymond–Roy class I) occurred in 71%. Twelve patients (86%) were discharged with mRS 0–2; one death (7%) was recorded. No timing or hemodynamic variable predicted discharge mRS (all P > 0.44; R2 ≤ 0.10). CONCLUSIONS: IPR was rare; when using pre-positioned neck-remodeling balloons or balloon-guide catheters, blood flow was stopped in just over a minute, and definitive hemostasis was achieved within ten minutes, leading to high rates of complete occlusion and functional independence. Transient blood pressure surges did not affect the outcome, indicating that rapid mechanical controls supported by careful microcatheter handling—are the key modifiable factors. These benchmarks require prospective validation in larger multi-center cohorts with continuous hemodynamic capture.

Fields of Study & Subjects

Intracranial Aneurysms: Treatment and Complications Vascular Malformations Diagnosis and Treatment Aortic aneurysm repair treatments

Publication details

Journal / source
Neurosurgery
Volume
72
Issue
Supplement_1
Pages
190–190
Publication date
26 March 2026
Language