1074 The Advent, Application, and Adoption of a Novel System for Robotic Deep Brain Stimulation Surgery

View at publisher Summarise with VIRAT
Authors: Alexander Craig McConnell Greven, Alexander T. M. Cheung, Baltazar Zavala, Kassu Mehari Beyene, Francisco A. Ponce
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

INTRODUCTION: Many neurosurgeons are adopting robotic systems for deep brain stimulation (DBS) for ease of use and reduction in human error. Different robotic systems have been described as safe with varying degrees of accuracy in mostly small case series. METHODS: Retrospectively reviewed 399 patients with DBS lead implantation (789 leads) from 9/2021-1/2025. Radial error (RE), operative time and lead revisions were evaluated. Cases utilizing Excelsius GPS (Globus Medical, Audubon, PA) were considered “robotic” while “non-robotic” cases used a Leksell frame. RESULTS: Forty-nine percent of cases were robotic. Mean RE for robotic cases was significantly lower than non-robotic cases (0.76 +/- 0.48 mm vs. 0.85 +/- 0.43 mm, p = 0.003). There was higher RE on the second lead compared to the first in non-robotic cases (0.92 +/- 0.47 mm vs 0.79 +/- 0.39 mm, p = 0.003), but no significant difference in RE in first and second lead placement in robotic cases (0.80 +/- 0.48 mm vs. 0.71 +/- 0.48 mm, p = 0.092). Robotic cases were longer than non-robotic cases (78.39 +/- 25.35 min vs. 70.16 +/- 26.35 min, p = 0.002). RE, operative time, and lead revisions for robotic cases improved with experience (1st quartile of cases RE 1.09 +/- 0.47 mm vs. 4th quartile 0.68 +/- 0.44 mm, p < 0.001; operative time 1st quartile 103.2 +/- 30.43 min vs. 4th quartile 69.27 +/- 18.77 min, p < 0.001; lead revisions 1st half of cases 14 revisions vs. 2nd half 2 revisions, p = 0.002). CONCLUSIONS: Robotic DBS placement demonstrates greater accuracy, decreased variability between first and second lead placement, and longer operative time that resolves with experience when compared to non-robotic DBS surgery.

Fields of Study & Subjects

Deep Brain Stimulation and Movement Disorders Obsessive-Compulsive Spectrum Disorders Botulinum Toxin and Related Neurological Disorders

Publication details

Journal / source
Neurosurgery
Volume
72
Issue
Supplement_1
Pages
197–198
Publication date
26 March 2026
Language
EN