1116 Correlation of Trans-Cranioplasty Point of Care Ultrasound to Computerized Tomography Following Subdural Hematoma Evacuation

View at publisher Summarise with VIRAT
Authors: Mark Constable, Nicholas A. Tomson, Victoria A. Schunemann, Shahid Mehdi Nimjee, Jennifer E. Kim
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

INTRODUCTION: Point of care (POC) ultrasound of the brain has significant potential to expedite diagnosis, decrease radiation exposure, and reduce healthcare costs if validated as an alternative to serial CT scans. Historically, ultrasound image acquisition in adults was limited to the intraoperative setting due to the poor penetration of sound through the cranium. However, the recent adoption of sonolucent cranial plates has opened the window for sonographic imaging of intracranial structures to be performed as a point of care ultrasound by bedside clinicians. METHODS: We performed a retrospective chart review of nine patient’s imaging comparing the most recent CT imaging to POC ultrasound imaging performed in the clinic setting. Measurements included (1) outer edge of sonolucent plate to cortical surface (which correlates to the subdural space on CT) and (2) outer edge of plate to ventricular septum. RESULTS: Trans-cranioplasty ultrasound was performed on nine subjects. Midline septum was identified in 6 of 9 studies, and cerebral cortical surface was identified in 8 of 9 studies. Of the recorded ultrasound measurements, midline averaged within 0.67 mm with SD of 2.18 mm and cortex measurement averaged within 0.13 mm with SD 2.07 mm when compared to their corresponding CT measurements. CONCLUSIONS: Successful POC trans-cranioplasty ultrasound imaging is feasible but operator dependent following SDH evacuation. Limitations to visibility of intracranial structures varied with presence of postoperative pneumocephalus or bioabsorbable sponges/dural regeneration matrices and patient comfort. The sensitivity and specificity of the imaging techniques requires a larger correlative study. This small sample size demonstrated feasibility and promising correlation between CT and ultrasound measurements.

Fields of Study & Subjects

Ultrasound in Clinical Applications Neurosurgical Procedures and Complications Traumatic Brain Injury and Neurovascular Disturbances

Publication details

Journal / source
Neurosurgery
Volume
72
Issue
Supplement_1
Pages
210–210
Publication date
26 March 2026
Language
EN