2082 Real-Time Tool Tracking and Surface-Tracing Registration for Augmented Reality Ventricular Navigation: A Controlled Study of Accuracy and Usability

View at publisher Summarise with VIRAT
Authors: Gabriel Urreola, Marc J. Fischer, Paolo Palmisciano, Matthew J. Kercher, Jared W. Clouse, Cameron Sadegh, Branden John Cord, Andrew Hernandez, Brandon Strong, Julia D. Sharma
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

INTRODUCTION: Emergent ventricular catheter placement demands high spatial accuracy, yet traditional freehand techniques remain error-prone and dependent on experience. Navigation platforms improve precision but are often limited by cost, setup time, and lack of portability. This study introduces a novel augmented reality (AR) navigation system for ventricular access using Microsoft HoloLens 2. The platform features a custom surface-tracing registration algorithm and real-time catheter tool tracking. METHODS: Pre-planned trajectories were overlaid to 3D-printed phantom heads using AR via stylus-based landmark registration and surface tracing. Catheter placements were performed in randomized order across two conditions: static in-situ AR visualization (IS) and real-time tool-tracked guidance (TT) using an infrared-tracked catheter. Ten users (neurosurgical faculty & residents) completed 12 insertions each. Post-insertion CT scans quantified errors in catheter entry, trajectory angle, depth, and radial deviation. Questionnaires administered. RESULTS: Tool-tracked AR significantly reduced errors across all key metrics: depth error (TT median 2.2 mm vs. IS 14.5 mm, p < 0.01), radial error (2.5 mm vs. 6.9 mm, p < 0.01), and angular deviation (2.3° vs. 4.3°, p < 0.01). Users reported significantly greater confidence and spatial awareness using TT, especially for assessing instrument angulation and depth. Setup time, including surface tracing, remained under two minutes and was rated clinically acceptable. This technology was translated clinically in two VP shunts. CONCLUSIONS: This study validates a novel AR registration and guidance system combining stylus-based surface tracing with real-time tool tracking. The platform offers significant accuracy gains over static overlays while maintaining rapid setup and intuitive use, demonstrating strong potential for clinical translation in neurosurgical navigation.

Fields of Study & Subjects

Augmented Reality Applications Anatomy and Medical Technology Surgical Simulation and Training

Publication details

Journal / source
Neurosurgery
Volume
72
Issue
Supplement_1
Pages
265–265
Publication date
26 March 2026
Language