267 Novel Imaging Modalities for Detecting Brain Arteriovenous Malformations: A Systematic Review and Meta-Analysis

View at publisher Summarise with VIRAT
Authors: Seyed Morsal Mosallami Aghili, Joyce Campos, Nicholas Kordic, Alfonse J. Mazzarella, Sujith Swarna, Chiemeka David Uwakwe, Zain Haider, Ali-Raza Hassan-Abdi, Charles B. Mikell, Sima Mofakham
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

INTRODUCTION: Accurate brain arteriovenous malformation (bAVM) diagnosis is challenging due to complex anatomy and limitations in visualizing key vascular details. There is a growing demand for non-invasive imaging techniques that offer high diagnostic accuracy. METHODS: A PRISMA-based systematic review was conducted across PubMed, Embase, Web of Science, and Scopus to identify studies published between August 2014 and August 2024. Eligible studies evaluated novel imaging techniques for initial bAVM diagnosis. Studies were screened by two independent reviewers. A random-effects model pooled sensitivity and specificity estimates. Heterogeneity was assessed using I2 statistics, and publication bias was evaluated via funnel plots and Egger’s test where applicable. RESULTS: Of 5,754 screened articles, 28 met inclusion criteria; 23 were included in the meta-analysis. Magnetic resonance angiography (MRA) demonstrated pooled sensitivity and specificity of 0.94 (95% CI: 0.86–0.98) and 0.94 (95% CI: 0.83–0.98). Among submodalities, 4D MRA (4 studies, 102 bAVMs) had the highest pooled sensitivity (0.95; 95% CI: 0.40–1.00), followed by susceptibility-weighted imaging (SWI; 4 studies, 164 bAVMs; 0.95; 95% CI: 0.61–0.99) and arterial spin labeling (ASL; 6 studies, 187 bAVMs; 0.93; 95% CI: 0.79–0.98). Computed tomography angiography (CTA) showed pooled sensitivity of 0.92 (95% CI: 0.58–0.99; 3 studies, 93 bAVMs) and specificity of 0.99 (95% CI: 0.00–1.00; 2 studies, 81 bAVMs). in subgroup analysis, time-resolved CTA was more sensitive than 4D CTA, with pooled sensitivities of 97% and 85%, respectively. Artificial intelligence (AI)–assisted techniques showed pooled sensitivity of 0.93 (95% CI: 0.41–1.00; 3 studies, 815 bAVMs) and specificity of 0.96 (95% CI: 0.00–1.00; 2 studies, 181 bAVMs). CONCLUSIONS: Novel imaging techniques demonstrate high diagnostic performance in detecting bAVMs. These innovations may reduce reliance on invasive angiography and support more accurate treatment planning.

Fields of Study & Subjects

Vascular Malformations Diagnosis and Treatment Advanced MRI Techniques and Applications Vascular Malformations and Hemangiomas

Publication details

Journal / source
Neurosurgery
Volume
72
Issue
Supplement_1
Pages
65–65
Publication date
26 March 2026
Language