495 IRRAsert: Affordable Simulator for Inserting IRRAflow Catheters
Neurosurgery 2026
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT
Free to try with your Science Catalogs account.
Abstract
INTRODUCTION: Neurosurgery is a distinctive realm with a tight and strict margin of error. Surgical skills are a major cornerstone where continuous infusion of simulation-based training systems is necessary. Simulation-based training started in BC mainly on animal models and cadavers then included wax models and mannequins in the 1800 and the 1950, respectively. Thereafter, simulation training progressed to include 3D prints and physical and virtual realities. The IRRAflow is an FDA-approved active cerebrospinal fluid (CSF) exchange system that can irrigate up to 180 ml/hr. the system is tightly secured, safe and continuously monitors intracranial pressure (ICP). It utilizes a 9-French dual-lumen catheter. Inserting an IRRAflow catheter is more complex than standard External ventricular drains (EVD). The process has extracranial and intracranial components. Hence, any possible breach of this system in terms of CSF leakage, infections, or iatrogenic brain injury occurs during this procedure. METHODS: The IRRAsert simulator was designed according to the catheter insertion methods reported by Garavaglia et al. The skull was 3D printed and made of polylactic acid (PLA) given the sturdiness and the low cost. material. the Kocher’s point was marked in the midline axis and 11 cm posterior to the nasion, then 3 cm laterally and corresponding to the mid pupillary line. an electric drill was used to drill the Kocher’s point of 1-2 mm. We used silicone to make the skin flap. A big bucket of skin was made which was then cut into squares each were 8mm thickness, then we used a 3D printed template to mold the cap to match the skull. No materials were used for to adhere the skin flap to the skull. The endogenous property of the starch in the PLA allowed adhesion with the silicone in the skin flap, which helped us rotate the flap after each insertion to save more money. Further, the alloy property of the siliconein the skin allowed for easy molding of the skin flap to fit over the skull. RESULTS: The IRRAsert simulator replicated the external parts of the skull starting from the bone outward. It allows measurements for designating the Kocher’s point, incising the skin to reveal the drilled Kocher’s point, tunneling under the scalp, and a 5 cm posterior exit incision. The adhesive characteristic of the allowed for dissection of skin from the bone and tunneling for the catheter under the scalp. Our simulator also at the end the skin layer is lifted up and rotated allowing another insertion. The total cost of our simulator is (30 USD), we only need to reproduce the skin which cost (50 USD) per a whole bucket. So the cost per learner is less than 10 USD. It is obvious that a major limitation to our simulator is lacking a brain tissue to mimic the intracranial component of the catheter placement. However, this simulator was designed to be affordable, reusable, and easily deployable to prevent the pitfalls that may happen when inserting and securing the IRRAflow catheter, especially with irrigation at a high speed. There are no unique pitfalls different from other standard EVD catheter when it comes to the intracranial component of catheter insertion, and this was already covered by other models. Further, it is worth mentioning that part of the treatment protocol when utilizing the IRRAflow technology is to do a mandatory CT scan before irrigation to detect any pitfalls related to the intracranial component of the IRRAflow catheter placement. Hence, having a simulator that includes the intracranial component while increasing the cost sounds challenging and inconsistent with our primary goal. Further, repetition is the mainstay of mastery, both are fulfilled by the affordability and the reproducibility of this simulator. CONCLUSIONS: IRRAsert is a result of multi-disciplinary efforts to produce the most affordable simulator which particularly focuses on the extracranial component of the IRRAflow catheter insertion to prevent major complications such as CSF leakage, infections, or iatrogenic brain injury.
Fields of Study & Subjects
Simulation-Based Education in Healthcare
Surgical Simulation and Training
Anatomy and Medical Technology
Publication details
- Journal / source
- Neurosurgery
- Volume
- 72
- Issue
- Supplement_1
- Pages
- 146–146
- Publication date
- 26 March 2026
- Language
- EN