Cavity Margins Sample Shaving as Part of Extended Vacuum-Assisted Breast Biopsy: A Potential Approach to Predict Percutaneous Breast Cancer Excision

Read full text
Authors: Paula Clarke, Eduardo Carvalho Pessoa, Bertha Andrade Coelho, Daniel de Araújo Brito Buttros, Aleida Nazareth Soares, Bruna Torres Silvestre, Hélio Rubens de Carvalho Nunes, Carla Priscila Kamiya Carvalho Pessoa, Amanda Cristina Braga de Oliveira, Tereza Cristina Ferreira de Oliveira, Bernardo Ferreira de Paula Ricardo, Paola Hartung Toppa
+21 more André P. L. Mattar, Marcelo Antonini, Heverton Leal Ernesto de Amorim, Gustavo Machado Badan, Ruffo Freitas‐Júnior, Marcus Nascimento Borges, Katyane Larissa Alves, Douglas de Miranda Pires, Shirley das Graças Ferreira, Gabriel de Almeida Silva, Romana Giordani Ribeiro Saliba, Ana Carolina Guglielmelli Mendonça, Larissa Barbosa Oliveira, Thaís Paiva Moraes, Cristina Milene Barbosa Maynart Aragão, Felipe Marcondes de Oliveira Coelho, Letícia Martins de Araújo Campos Linhares, Heloísa De Luca Véspoli, Annamaria Massahud Rodrigues dos Santos, Mayne Cardoso Cani, Henrique Lima Couto
Cited by: 1
References: 29

Abstract

BACKGROUND: Excision of small breast cancers has been reported by vacuum-assisted biopsy (VAB). Nevertheless, patients are submitted to surgery, because there is no way to predict excision. The purpose of this study was to evaluate extended vacuum-assisted biopsy (EVAB) associated with cavity margins sample shaving (CMSH) to predict breast cancer excision. METHODS: This is a retrospective database analysis of 120 cancers [both invasive breast cancers (IC) and ductal carcinoma in situ (DCIS)] diagnosed by EVAB-CMSH submitted to surgery with histological data from EVAB-CMSH and surgery. The CMSH was evaluated as a diagnostic test for excision compared to surgery as gold standard. Factors associated with residual tumor, gross residual tumor (GRD) (> 3 mm), and false-negative CMSH after EVAB-CMSH were evaluated. RESULTS: A total of 120 cases were analyzed. Media age was 57 (48.5-69); image tumor size (T) was 11 (8.6-15) mm; pathological tumor size (pT) was 6 (4-10) mm; most cases IC+DCIS 53 (44.2%), DCIS 46 (38.3%), and IC 15 (12.5%); 45 (37.5%) were excised by EVAB-CMSH. CMSH sensitivity 70.7%, specificity 66.7%, false-negative rate 18.33%, and accuracy 69.2%. In multivariate analysis, DCIS pT (p = 0.003, odds ratio [OR] 1.46, 95% confidence interval [CI]) was associated with residual tumor; DCIS pT (p = 0.001, OR 1.34, 95% CI) and the CMSH T (p = 0.001, OR 1.67, 95% CI) with GRD; surgical specimen DCIS T (p = 0.015, OR 1.12, 95% CI) with CMSH false negative. CONCLUSIONS: Cavity margins sample shaving is a potential approach to predict small breast cancer excision and should be added to vacuum-assisted excision in prospective trials. For DCIS, EVAB-CMSH should not be standard of care.

Fields of Study & Subjects

Breast Cancer Treatment Studies Breast Lesions and Carcinomas Global Cancer Incidence and Screening

Publication details

Journal / source
Annals of Surgical Oncology
Publisher
Springer Science and Business Media LLC
Publication date
28 August 2026
Language
EN