A novel predictable analogue workflow for passive full-arch implant prostheses

View at publisher Summarise with VIRAT
Authors: Ricky Bhopal, Kevin Armstrong, Pynadath George
Cited by: 0
References: 30

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Achieving the passive fit of a long-span, fixed bridge onto multiple implants remains challenging despite advances in digital workflows. Errors during impression taking, model construction and framework fabrication may accumulate, resulting in mechanical and technical complications. This article describes a structured analogue workflow, incorporating the passive analogue impression technique (PAIT) jig. The philosophy, material considerations and step-by-step clinical and laboratory procedures are presented. Emphasis is placed on rigidity, control of composite polymerization shrinkage, dimensional expansion of plaster and systematic verification of passivity. When executed without shortcuts, the PAIT workflow provides a predictable and transparent pathway to achieving passivity in long-span implant bridges. CPD/Clinical Relevance: Clinicians must understand both the material science and the various verification techniques to minimize the potential misfit of the implant bridge.

Fields of Study & Subjects

Dental Implant Techniques and Outcomes Dental materials and restorations Scientific and Engineering Research Topics

Publication details

Journal / source
Dental Update
Volume
53
Issue
Sup1
Publication date
1 March 2026
Language
EN