Italian Journal of Anatomy and Embryology - contenuto non piu disponibile

Read full text
Authors: Veronica Macchi, Andrea Porzionato, Cesare Tiengo, Diego Guidolin, Carla Stecco, Gloria Sarasin, Anna Rambaldo, Andrew D. A. Maidment, Predrag R. Bakić, Raffaele De
Cited by: 3

Abstract

Breast tissue simulation is of importance for developing anthropomorphic phantoms used for preclinical testing or optimization of imaging systems or image analysis methods. Recently a new breast anatomy simulation method performs a direct calculation of the Cooper’s ligaments (i.e., the borders between simulated adipose compartments), using arbitrary selected values for the size of adipose lobuli and the thickness of the fibrous septa (Cooper’s ligaments) enveloping these lobuli. The aim of the present study was to perform anatomo-microscopic study of the structure of the human breast to improve the realism of simulation. Surgical samples during procedure for breast reduction (45 and 38 y-old) or breast mastopexy in ex-obese patients (52 and 39 y-old) were sampled. In 2 un-embalmed cadavers (53 and 68 y-old) mastectomy were performed. The samples were full thickness specimens from the skin to the deep fascia, one for each quadrant of the breast. From the histo-topographic point of view the breast tissue showed a stratigraphic organisation, with the following layer: skin, superficial fibro-adipose tissue, superficial fascia, deep fibro-adipose tissue and glandular tissue. On slides stained with azan-Mallory morphometric evaluation was performed with image analysis software. The values of the adipose tissue (AT) lobules area and axial ratio were 0.84 ± 0.04 cm3 and 2.02 ± 0.14 at the level of subcutaneos AT compartments, 0.94 ± 0.07 cm3 and 2.91 ± 0.30 at the level of deep AT, and 0.26 ± 0.01 cm3 and 2.04 ± 0.12 at the level of periglandular AT. The values of the volume fraction of the connective tissue and of the mean thickness of the connective tissue branches delimiting the lobules were 12.3 ± 1.4 % and 289.2 ± 13.0 μm. Our data were comparable with the value (400 micron) that has been used in the new breast anatomy simulation method which showed realistic appearance of synthetic images. Preclinical validation is of particular interest in development of systems for early breast cancer screening.

Fields of Study & Subjects

Breast Cancer Treatment Studies Breast Implant and Reconstruction Breast Lesions and Carcinomas

Publication details

Publisher
Firenze University Press
Volume
117
Issue
2
Pages
105
Publication date
8 July 2026
Language
EN