Evaluation of an automated SPE method for samples derived from capillary microsampling

Read full text
Authors: Paul‐Gerhard Lassahn, Petra Lombardi, Winfried Wagner‐Redeker, Marie-Claude Roubaudi-Fraschini, Bolliger, Reto, Guenter Boehm
Cited by: 0

Abstract

Experimental Samples were processed by dilution of spiked plasma with water containing the internal standard followed by online sample-preparation described below. Working-solutions and sample preparation: The analyte (MW 581) was dissolved in DMSO and diluted in ACN/ DMSO (50:50, v/v) to obtain working-solutions at concentrations twenty times higher than those of the final CAL and QC samples. Aliquots of the working-solutions were spiked into blank rat plasma and diluted with water containing the internal standard in a ratio of 1:10 (v/v). The samples were vortexed, centrifuged and transferred to the ITSP sample-preparation plate. Online-sample-preparation: ITSP (ITSP Solutions Inc.) cartridges were conditioned with 80µL MeOH and 80µL 0.2% aqueous formic acid before loading 10µL sample. After drying the cartridge with 80µL air, the ITSP cartridges were washed twice with 80µl 0.2% aqueous formic acid and dried again. The compounds were eluted using 80µL EtOH and 10µL of the eluate was injected onto the analytical column. Sample-preparation of each plasma sample was performed directly before the injection (see Figure 1 for the workflow and the results of the optimization process). Chromatography: 10 µL of the extracted samples were injected onto a Thermo Hypersil Gold (2.1 x 100 mm, 3 µm) analytical column. Eluent A consisted of 0.5% aqueous formic acid, eluent B of 0.5% formic acid in ACN and LC flow rate was 0.5 mL/min. The eluent composition was changed linearly from 70% to 5% A in 2.25 minutes. Eluent composition was kept at 5% B for one minute and then went back ballistically to starting conditions. Calibration range: 50.0 - 25’000 ng/mL (high-range, HR) and 5.00 - 2’500 ng/mL (low-range, LR). Instrumentation and MS-method: TSQ Quantum Ultra (Thermo Scientific), Rheos 2200 quarternary pump (Flux Instruments), HTX PAL autosampler (CTC Analytics). Data-Processing: Raw data were acquired with Xcalibur 2.0 software and processed with LCQuan 2.5 (Thermo Scientific). Validation parameters: Intra- and inter-assay accuracy and precision, linearity, and carry-over. Table 1. MS-parameter (SRM-assay). www.swissbioanalytics.com

Fields of Study & Subjects

Microfluidic and Capillary Electrophoresis Applications Analytical chemistry methods development Electrochemical Analysis and Applications

Publication details

Publication date
1 January 2026
Language
EN