Comparison of consumer-grade wearable devices with a research-grade instrument for measuring physical activity in a free-living setting

Read full text
Authors: Takuya Miwa, Kazuma Mii, Ryouichi Chatani, Yasuo Sugitani
Cited by: 2
References: 15

Abstract

INTRODUCTION: Wearable accelerometer devices are now widely used in both research and daily life settings. This study aimed to compare the accuracy of three commercially available consumer-grade activity monitors with the medical-grade ActiGraph device in a free-living setting in Japan. METHODS: Thirty-six office workers were enrolled and provided with an ActiGraph. Data were analyzed from participants who also wore Apple Watch (n = 21), Fitbit (n = 22), and Oura Ring (n = 5) over a 3-week period. Step count, physical activity energy expenditure (PAEE), and moderate-to-vigorous physical activity (MVPA) data were collected from all devices. Data were analyzed using correlation coefficients, mean differences, and Bland-Altman plots. RESULTS: ActiGraph data confirmed comparable physical activity levels across the participant subgroups, ensuring a valid basis for the subsequent inter-device comparisons. Step counts were largely consistent across devices, with Apple Watch and Oura Ring measurements within 10% of ActiGraph measurements (mean percentage differences 2.12% and -6.24%, respectively), while the Fitbit overestimated step count by 18.00%. MVPA showed greater variability, with Apple Watch and Oura Ring underestimating by 46.22% and 11.64% respectively, whereas the Fitbit showed minimal mean difference (0.62%). PAEE showed the largest discrepancies, with Apple Watch and Fitbit overestimating by 25.91% and 139.19% respectively, and Oura Ring underestimating by 16.87%. Correlation coefficients were strong for step counts (r = 0.84-0.92) but lower for MVPA and PAEE across all devices. Bland-Altman analysis revealed proportional bias in the Fitbit's PAEE and the Apple Watch's MVPA, with errors increasing at higher activity levels. CONCLUSION: Step counts were largely consistent with the ActiGraph for most devices; however, the Fitbit showed a notable overestimation. However, the ability of those devices to accurately measure MVPA and PAEE appeared to be more limited, particularly at higher activity levels. These findings underscore that the selection of a consumer-grade wearable for research or clinical use must be carefully guided by the specific metric of interest. However, the findings for the Oura Ring should be interpreted with caution due to the small sample size.

Fields of Study & Subjects

Physical Activity and Health Context-Aware Activity Recognition Systems Mobile Health and mHealth Applications

Publication details

Journal / source
PLoS ONE
Publisher
Public Library of Science (PLoS)
Volume
21
Issue
2
Pages
e0342543–e0342543
Publication date
23 February 2026
Language
EN