Study on modular smoke extraction with solid screen in urban road tunnel fires

Read full text
Authors: Xiaotao Zhang, Kaihua Lu, Yushi Lu
Cited by: 0
References: 29

Abstract

A series of numerical simulations were conducted to evaluate and optimize a modular smoke extraction system integrated with smoke screens for urban road tunnel fires. The study aimed to identify key design parameters and propose optimal strategies for tunnel-wide smoke management. The results show that smoke screen height is a critical factor, with a threshold of 1.5 m (25% of tunnel height) significantly enhancing extraction efficiency and reducing high-temperature zones, while vent-screen distance has minimal impact. Dividing the tunnel into five modular zones achieves the optimal balance between hazard control and system cost. Furthermore, an unbalanced airflow distribution strategy-allocating 35% of the total exhaust volume (180 m³/s) to proximate vents and 15% to distal vents-proves most effective in preventing plug-holing phenomenon and maximizing CO extraction efficiency. These findings provide specific design thresholds and actionable strategies for the optimization of transverse smoke extraction systems in urban road tunnels.

Fields of Study & Subjects

Fire dynamics and safety research Wind and Air Flow Studies Fire Detection and Safety Systems

Publication details

Journal / source
PLoS ONE
Volume
21
Issue
2
Pages
e0342557–e0342557
Publication date
17 February 2026