Thermodynamic performance analysis of an air conditioning system integrated with A solid desiccant dehumidifier wheel using solar reactivation

Read full text Summarise with VIRAT
Authors: Shriramshastri Chavali, Ravikant Keshav Nanwatkar, Sachin V. Mutalikdesai, Tarang Shinde, Aparna M. Bagde, Pravin T. Nitnaware, Shruti Dikshit, Sourabh Kulkarni
Cited by: 0
References: 31

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

The present study investigates the thermodynamic performance of an air-conditioning system integrated with a solid desiccant dehumidifier wheel (SDDW) using a combined heating mode of electrical and solar heaters.The obtained results were compared with standard results.During the experimentation, the solid desiccant wheel with silica gel as an adsorption material was used along with a conventional vapour compression cycle.The effect of inlet air temperature in the range of 23.6 °C to 37.2 °C and air inlet velocity in the range of 1.5 m/s to 4.1 m/s on the thermodynamic performance of an air-conditioning system integrated with a solid desiccant dehumidifier wheel was experimentally investigated.A combined electrical and solar heater mode was used to supply regeneration air for the solid desiccant dehumidifier at a constant velocity of 4.5 m/s.Experimentation was performed in all three seasons, namely summer, rainy and winter, to find the effect of seasonal variation on the performance of the air-conditioning system.The dehumidification effectiveness and adsorption rate in all three seasons increased with a decrease in the air inlet temperature.A maximum experimental value of dehumidification effectiveness was obtained in the summer season.At 23.6 °C and 1.5 m/s air inlet velocity, the maximum value of dehumidification effectiveness was 0.19.While at the same temperature, the maximum value of the adsorption rate at 4.1 m/s air inlet velocity was 0.4 kg/hr.In all three seasons, regeneration effectiveness increased with an increase in the inlet air temperature.While the regeneration effectiveness was reduced due to an increase in air let velocity.A maximum value of dehumidification effectiveness obtained in the summer season at 37.2 °C inlet air temperature and 1.5 m/s velocity was 0.298.The coefficient of Performance in all three seasons for the vapour compression cycle decreased with an increase in the inlet air temperature and ve-

Fields of Study & Subjects

Adsorption and Cooling Systems Refrigeration and Air Conditioning Technologies Building Energy and Comfort Optimization

Publication details

Journal / source
Journal of Thermal Engineering
Volume
12
Issue
2
Pages
665–683
Publication date
1 January 2026
Language
EN