Biases due to widespread use of low-cost sensors for urban heat stress assessments

Read full text Summarise with VIRAT
Authors: Sarah Berk
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Project Title: Biases due to widespread use of low-cost sensors for urban heat stress assessments Contact: Sarah Berk, sberk@unc.edu Description: This dataset accompanies the manuscript “Biases due to widespread use of low-cost sensors for urban heat stress assessments”. It contains measurements from low-cost air temperature and humidity sensors deployed in different experimental setups to quantify biases due to siting and shielding practices. The dataset includes eight calibration experiments (a–h) described below, along with derived variables (heat index, humidex) and reanalysis data used (ERA5). a: Urban lawn deployment. Sensors placed on urban lawn within radiation shields b: Rooftop deployment. Sensors placed on urban rooftop within radiation shields c: Shielded vs unshielded. Sensors placed on urban lawn within and without radiation shields, alternating. Sensors with radiation shields are denoted with the c_Shield_on field (True/ False) d: Near HVAC outlet. Sensors placed near a HVAC outlet on the urban rooftop within radiation shields. e: Controlled Environment. f: Shield Setup Test. Sensors placed in two different formats within radiation shields. Either secured via mounting based at the bottom of the shield, or suspended hanging from wire within the shield. Sensors on mounting based are denoted with the f_Mounting_base_secured field (True/ False). g: Plant Growth Chamber. Sensors placed in chamber with temperature sequentially set to 30, 25, and 20 °C for 6 h each, while relative humidity was stepped from 90 to 65 to 40 % for 2 h per step (18 h total). h: Horace Williams airport. Sensors placed on airport near research grade reference station. Data Fields: Calibration_Label: Label for the calibration (a-f) Calibration_Desc: Description of setup Sensor_ID: Unique sensor identifier Date_Time: Date and time of measurement (EDT) Air_Temperature: Measured air temperature (°C) Relative_Humidity: Measuredrelative humidity (%) Heat_Index: Heat index (°C), calculated from air temperature and relative humidity Humidex: Humidex, calculated from air temperature and relative humidity ERA5_shortwave_solar_radiation_downwards: shortwave solar radiation downwards (W/m²), taken from ERA5 reanalysis (DOI: 10.24381/cds.e2161bac) c_Shield_On: Only used for calibration c, True for sensors with shields on, False for those with no shield f_Mounting_base_secured: Only used for calibration f, True for sensors secured on mounting base, False for sensors suspended within shields. File Information: File format: CSV Time resolution: 10 minutes Usage Notes Calibration labels (a–h) should always be interpreted alongside the setup descriptions above. Derived fields (Heat Index, Humidex) are based on standard formulas; see manuscript for details. ERA5 radiation is matched by nearest grid cell (the same for both urban lawn and rooftop locations). Citation If you use this dataset, please cite: Berk, S. et al (2025). Biases due to widespread use of low-cost sensors for urban heat stress assessments doi:10.15139/S3/LMALFL [Dataset]

Fields of Study & Subjects

Urban Heat Island Mitigation Thermoregulation and physiological responses Wind and Air Flow Studies

Publication details

Journal / source
UNC Dataverse
Publication date
26 March 2026
Language
EN
Document type
Dataset