Hybrid quantum sensing using an optomechanical resonator coupled atom interferometer
Abstract
Quantum sensing using atom interferometry possesses immense potential for application in gravimetry, inertial navigation and for gravitational wave detection, apart from carrying out tests of fundamental physics. Atom interferometry can be used to perform absolute inertial measurements with unprecedented long term stability, unlike classical sensors which are prone to drift and incur calibration errors. However, atom interferometers seldom achieve their fundamental sensitivity due to the coupling of ambient vibrations. It is the dominant noise source that not only impairs performance but also affects its operability. Ideal compensation of the effects due to vibration noise using a versatile accelerometer, while concurrently enabling miniaturized atom interferometer setups has not been pioneered. Such a compact hybrid quantum sensor will enable reliable operation with an enhanced performance in field applications, paving the way for robust atom interferometry beyond laboratory conditions. A novel optomechanical resonator has been designed, developed and successfully hybridized with an atom interferometer to suppress the effects of vibration noise, and the results are presented in this thesis. The optomechanical resonator’s inertial test mass is simultaneously used to create a continuous intracavity optical lattice to sense its displacement, and a pulsed optical lattice to manipulate the atoms. For the first time, a broadband accelerometer is seamlessly hybridized with an atom interferometer via mechanical resonator mediated coupling of the optical lattices to measure acceleration. This enables elimination of vibration induced measurement ambiguity in our atom interferometer with a well defined mechanical transfer function. Vibration noise correlation is demonstrated up to our prototype atom interferometer’s most sensitive operating mode of T = 6 ms using double Bragg diffraction, ultimately limited by its technical noise. The optomechanical resonator measures acceleration with a sensitivity down to 1.1×10−6 ms−2/ √Hz corresponding to a displacement sensitivity of 8.6 × 10−15 m/ √Hz. Substantial 1/f noise suppression due to the developed optical readout scheme enables a measurement bandwidth spanning from sub-hertz frequencies up to several kilohertz. Multiple versions of the optomechanical resonator with different characteristics were developed and hybridized with our atom interferometer. This paves the way for developing tailored optomechanical resonators for specific inertial sensing applications.
Fields of Study & Subjects
Mechanical and Optical Resonators
Geophysics and Sensor Technology
Cold Atom Physics and Bose-Einstein Condensates
Publication details
- Journal / source
- Leibniz Universität Hannover
- Publication date
- 1 January 2026
- Language
- EN
- Document type
- Thesis