Optimizing temporal resolution to reduce radiation dose in cerebral perfusion CT: a feasibility and stability study based on perfusion parameter assessment

Read full text
Authors: HU Juntao, LI Sui
Cited by: 0

Abstract

Abstract Objective To investigate the feasibility of reducing radiation dose in cerebral perfusion CT (CTP) while maintaining diagnostic accuracy by optimizing temporal resolution. Methods This retrospective cohort study included 117 stroke-suspected patients undergoing CTP at the First Affiliated Hospital of Army Medical University from January to September 2025. Three protocols were designed: Protocol 1 (full temporal resolution, 21-phase acquisition, baseline), Protocol 2 (every-other-phase sampling),Protocol 3 (peak-enhancement +1/-1 phase retention with every-other-phase sampling for remaining phases). Radiation reduction percentages relative to Protocol 1 were calculated. Regions of interest (ROI) were placed in ischemic core/penumbra to measure mean±SD of perfusion parameters: time to maximum of the residue function (Tmax), mean transit time(MTT), cerebral blood volume(CBV) and cerebral blood flow(CBF). Inter-protocol differences were assessed, and ischemic penumbra volume discrepancies were also analyzed. Results Protocol 2 and 3 reduced radiation dose by 50.0% and 42.9% versus Protocol 1, respectively. For perfusion parameters: Tmax SD differed significantly across protocols [F(1.92,222.42)=11.17, P

Fields of Study & Subjects

Radiation Dose and Imaging Acute Ischemic Stroke Management Advanced MRI Techniques and Applications

Publication details

Journal / source
DOAJ (DOAJ: Directory of Open Access Journals)
Publication date
1 February 2026
Language
ZH