Peculiarities of thermal operation of grate cooler of cement clinker
Abstract
One effective particulate cooler is a grizzly cooler that uses a cross-heat exchange scheme. According to its material balance, the bulk of the materials in it are streams of cold air from the atmosphere (57.37 %), discharged into the atmosphere with a temperature of 114 °C (23.85 %) and supplied to the furnace with a temperature of 404 °C (33.52 %). During its operation, three sources of dust removal are observed: dust returned to the finished product after gas cleaning (0.04 %), dust discharge to the atmosphere (0.02 %) and to the furnace with hot blast (7.1 %). The thermal efficiency of the grate cooler is 88.11 %.To reduce the final temperature of the clinker, it is advisable to install inclined plates in the supply and exhaust gas headers to change their gas-dynamic resistance. Ill. 3. Ref. 6. Tab. 2.
Fields of Study & Subjects
Heat Transfer and Optimization
Granular flow and fluidized beds
Diverse Industrial Engineering Technologies
Publication details
- Journal / source
- NOVYE OGNEUPORY (NEW REFRACTORIES)
- Issue
- 5
- Pages
- 14–18
- Publication date
- 13 January 2026