Percutaneous dilatational tracheostomy associated with mismatched tracheostomy tubes and introducer sets in a 57-year-old Korean man: a case report
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
Percutaneous dilatational tracheostomy (PDT) is widely used for prolonged ventilation; however, dilatation-related complications may be underrecognized. We report a complication of tracheostomy malposition induced by tissue stretching during PDT, in which an excessively dilated tract fails to recoil adequately around the tube, compromising the cuff seal. A 57-year-old Korean man was admitted for recurrent seizures. PDT was performed under bronchoscopic guidance without immediate complications. Three days after the first PDT, partial tracheostomy tube dislodgment resulted in a 40%–60% ventilator leak. Sedation, tube reinsertion, and cuff reinflation were attempted; however, the leak worsened to 99%, necessitating rapid sequence intubation. Retrospective review of the bronchoscopic images demonstrated tracheal tissue stretching during initial insertion, suggesting excessive traction on the anterior tracheal wall. A size mismatch between the loading dilator and the tracheostomy tube likely created a gap that allowed tracheal tissue to be drawn into the tract and then recoil, contributing to malposition. Clinicians should recognize this potential complication, monitor for high ventilator leak rates, cuff-pressure abnormalities, and radiographic malalignment, and be prepared to perform repeat tracheostomy or endotracheal intubation if necessary.
Fields of Study & Subjects
Tracheal and airway disorders
Airway Management and Intubation Techniques
Respiratory Support and Mechanisms
Publication details
- Journal / source
- JOURNAL OF ACUTE CARE SURGERY
- Volume
- 16
- Issue
- 1
- Pages
- 49–53
- Publication date
- 26 March 2026
- Language
- EN