Dual-Stage Relief Valve for Sub-Critical Pressure Transients and LCF Suppression in Electro-Hydraulic Hammers
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
To address low-cycle fatigue in electro-hydraulic hammers induced by sub-critical pressure fluctuations (35–40 MPa), which conventional valves fail to mitigate due to a response “dead zone”, this study proposes a dual-stage relief valve with a fixed geometric differential area. This design decouples high- and low-pressure regulation, integrating a direct-acting stage for surges (>40 MPa) with a pilot stage for sub-critical transients to eliminate the blind spot. Structural parameters were optimized via sensitivity analysis. Validated by AMESim/Simulink co-simulation and experiments, the valve achieves a 20 ms response time—40% faster than conventional valves—and reduces fluctuation amplitudes from 5 MPa to 1.5 MPa. Stress analysis indicates cyclic stress reduction from 108.1 MPa to 43.2 MPa. Consequently, predicted service life extends from 9.6×10⁴ to 9.8×10⁶ cycles, increasing by nearly two orders of magnitude. This design shifts from reactive protection to proactive stability management, enhancing heavy-duty hydraulic system reliability.
Fields of Study & Subjects
Hydraulic and Pneumatic Systems
Water Systems and Optimization
Engineering Applied Research
Publication details
- Journal / source
- Eksploatacja i Niezawodnosc - Maintenance and Reliability
- Publication date
- 23 March 2026
- Language
- EN