Upgrade and evolution of the ad target beam imaging system at CERN: a two-year performance analysis

Read full text
Authors: Stephane Burger, F. Roncarolo, Javier Martínez Samblas, Manuel Gonzalez-Berges
Cited by: 0

Abstract

During CERN’s Long Shutdown 2 (LS2) in 2022, the Anti-Proton Decelerator (AD) target area underwent major renovations, including a significant upgrade to its beam imaging system. The previous tube-based camera, used in a high-radiation environment, had limitations in sensitivity and resolution for continuous measurements. The upgraded design uses an innovative in-air light-emitting screen mechanically coupled to the AD target, monitored by a digital camera through a 20-meter optical line from a radiation-safe zone. This setup improves accessibility during beam operation and enhances measurement capabilities. Over two years of operation, several crucial modifications were made. A key change was transitioning from a scintillation material screen to an Optical Transition Radiation (OTR) screen, though this created new challenges with background interference. To address temperature-dependent calibration variations, an automated calibration mechanism was developed, utilizing advanced image analysis algorithms for real-time adjustments. This paper discusses these developments, challenges, solutions, and future optimization opportunities for the AD facility’s evolving experimental needs.

Fields of Study & Subjects

Particle accelerators and beam dynamics Particle Detector Development and Performance Particle Accelerators and Free-Electron Lasers

Publication details

Journal / source
CERN Document Server (European Organization for Nuclear Research)
Publication date
20 January 2026
Language
EN