Design and Programming of a Multifunctional Device for Accelerator Beam Profile Measurement and Beam Stop

Read full text
Authors: Fang Li, Lei Zeng, Muhammad Abdul Rehman, Ruiyang Qiu, Zhihong Xu, Weiling Huang, Yongjia Lv, Renjun Yang, Rui Yang
Cited by: 0

Abstract

During the pre-research phase of China Spallation Neutron Source (CSNS) upgrade project (CSNS-II), in order to conduct beam commissioning of the Radio Frequency Quadrupole (RFQ) under high-intensity beam conditions, The structure of the last-stage wire scanner of the Medium Energy Beam Transport (MEBT) was innovatively modified. This modification not only added a Beam Stop but also significantly enhanced the efficiency of wire scanner. This paper presents the architecture and operational programming of a novel multifunctional device designed for accelerator beam diagnostics and beam termination: beam profile measurement via advanced sensing mechanisms and Beam Stop using a braided carbon fiber plate as the primary beam stop.

Fields of Study & Subjects

Particle accelerators and beam dynamics Particle Detector Development and Performance Magnetic confinement fusion research

Publication details

Journal / source
JACOW
Publication date
20 January 2026
Language
EN