From simulation to measurement: Enhancing FE simulation for PETRA IV and EuXFEL girders

Read full text Summarise with VIRAT
Authors: Daniel Thoden, Normann Koldrack
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Finite element analyses provide high-accuracy results when analysing monolithic parts like girders for accelerator components. To account for the supports and loads, simple entities such as springs and single-point masses are added to the model during design and development. However, the mechanical properties of real-world parts are often estimated, leading to deviating results, particularly on low-frequency modes, when measured in situ. To address this issue, a method is demonstrated using vibration measurements on a topology-optimised girder for the PETRA IV synchrotron radiation facility. This method allows for tuning the simulation properties accordingly. Even with simple models, an excellent correlation between measurement and simulation, spanning a wide range of modes, can be achieved. The results are then applied to different girder setups for the European XFEL to validate the approach. By comparing simulation and measurement of girders made from welded steel and ultra-high-performance concrete, the robustness of the method is discussed.

Fields of Study & Subjects

Mechanical Engineering Research and Applications Particle Accelerators and Free-Electron Lasers Structural Health Monitoring Techniques

Publication details

Journal / source
JACOW
Publication date
2 April 2026
Language