XBPF design and prototyping

Read full text Summarise with VIRAT
Authors: Benjamin Moser, Alexandre Frassier, Emma Buchanan, I. Ortega, R. Larsen
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

The CERN Beam Instrumentation Group has developed a new scintillating fibre beam profile monitor for the secondary beam lines of the CERN North Experimental Area. This innovative monitor employs plastic scintillating fibres, read out with silicon photomultipliers, to provide a cost-effective and efficient solution for beam profile measurement. The design goals for the new monitor included ease and low cost of production, achieving a particle detection efficiency above 95%, compatibility with beam intensities ranging from 1 to 10^8 particles per second, a spatial resolution of 1 mm, a low material budget, coverage of an active area of 10 cm x 10 cm and 20 cm x 20 cm, operability in a vacuum environment, and equipped with in/out motorisation for retracting the equipment from the beamline. A prototype was tested at the CERN East and North Area facilities, demonstrating excellent performance and validating the design for mass production.

Fields of Study & Subjects

Particle Detector Development and Performance Radiation Detection and Scintillator Technologies Particle accelerators and beam dynamics

Publication details

Journal / source
CERN Document Server (European Organization for Nuclear Research)
Publication date
2 April 2026
Language
EN