GA-optimized FOPID control for LVRT enhancement in PV–EV integrated power systems

Read full text Summarise with VIRAT
Authors: Ibrahim A. Altarjami
Cited by: 0
References: 30

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Rapid growth in electric vehicle (EV) deployment, combined with high photovoltaic (PV) penetration, is reshaping the dynamic behavior of transmission networks. As PV inverters displace synchronous machines, the resulting loss of rotational inertia heightens vulnerability to fault-induced voltage sags and oscillatory instability. Co-located EV charging loads further stress weakened voltage profiles, increasing the risk of failing low-voltage ride-through (LVRT) requirements. This paper proposes a genetic algorithm (GA)-optimized fractional-order PID (FOPID) controller with five tunable parameters (Kp, Ki, Kd, λ, μ) to regulate the voltage/reactive-power output of an EV aggregator at a critical load bus. A conventional three-gain PID controller optimized by the same GA under identical cost function and constraints serves as the benchmark. Both controllers are evaluated on the Kundur two-area system in PSS®E, where Buses 1 and 3 host PV plants supplying 50% of generation while Buses 2 and 4 retain synchronous excitation. The EV aggregator at Bus 7 is modeled using WECC second-generation generic converter modules with a negative-generation sign convention, and the FOPID action is discretized via Grünwald–Letnikov recursion. Under a solid three-phase fault on the Bus 7–8 tie-line cleared after 100 ms, the GA-FOPID controller recovers Bus 7 voltage to the 0.9–1.1 pu band within 250 ms and maintains 95% in-band operation over the 4 s post-fault window. The GA-PID controller fails to stabilize the system, causing interconnection separation, while the uncontrolled case collapses entirely. Inter-area rotor-angle traces confirm GA-FOPID confines the first post-fault swing and damps subsequent oscillations, whereas neither alternative maintains synchronism, demonstrating that fractional-order parameters measurably improve LVRT compliance and transient damping in PV–EV co-located systems.

Fields of Study & Subjects

Power System Optimization and Stability Microgrid Control and Optimization Frequency Control in Power Systems

Publication details

Journal / source
Clean Energy Science and Technology
Publication date
27 March 2026
Language
EN