Application of Flow Injection System to Ascorbic Acid Assay for Assessing Oxidative Potential of Metal Ions
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
Human exposure to fine particulate matter (PM 2.5 ) air pollution is known to cause adverse health outcomes.The mechanisms by which PM 2.5 affects human health are not yet fully understood.However, accumulating evidence indicates that PM exposure induces oxidative stress via the generation of reactive oxygen species (ROS), a process often characterized by its oxidative potential (OP).Therefore, reliable tools are needed to estimate the oxidantgenerating capacity of PM.One of the most widely reported methods for assessing PM oxidative potential is the ascorbic acid (AA) assay.This assay employs chemical analysis to determine the time-course of the aqueous AA concentration during its reaction with chemical species present in PM 2.5 .The depletion rate of AA in solution is referred to as the OP of the test sample.The AA concentration is quantified by conventional spectrophotometry at a wavelength of 265 nm.However, determining the AA depletion rate requires multiple measurements on a single sample, making it a labor-intensive method when analyzing large numbers of samples.The purpose of this study is to develop a more simplified and userfriendly AA assay by applying a flow injection (FI) system to measure the oxidation rate of AA.The FI system was constructed based on an ultrafast liquid chromatography setup without a chromatographic column.Dilution series of Cu(II) and Fe(II) were prepared, and their OP values were investigated by absorptiometry at 265 nm using the constructed FI system.As a result, the AA depletion rate increased with rising concentrations of both metal ions in solution.The OP values were compared with those obtained via traditional spectrophotometry.The results indicated no statistically significant differences between OP values measured by the two methods, demonstrating the successful application of the FI system for OP measurement.
Fields of Study & Subjects
Analytical chemistry methods development
Atmospheric chemistry and aerosols
Antioxidant Activity and Oxidative Stress
Publication details
- Journal / source
- Institutional Repositories DataBase (IRDB)
- Volume
- 61
- Pages
- 8–15
- Publication date
- 20 March 2026
- Language
- EN