SEM-EDS Catalog of Potential Contaminant Particles in the Ryugu Sample Clean Chamber (CC4-1 and CC4-2)

Read full text Summarise with VIRAT
Authors: Rei Kanemaru, Masahiro Nishimura, Kentaro Hatakeda, Akiko Miyazaki, Kazuya Kumagai, Yuya Hitomi, Toru YADA, Ryota Fukai, Haruna Sugahara, Masanao Abe, T. Okada, Tomohiro Usui
+1 more Astromaterials Science Research Group
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

This report presents the first investigation focusing on particles present in clean chambers used for storing asteroidal return samples. Such particles are expected to serve as potential contamination sources for the returned samples, and their characterization is an urgent task at a time when scientific results from the return samples are actively being published. Therefore, in this investigation, particles were collected from the Ryugu sample clean chambers (i.e., CC4-1 and CC4-2) using tweezers and vacuum tweezers, analyzed by SEM-EDS, and cataloged. A total of 94 particles/microparticles were identified, consisting mainly of stainless steel (SUS304-like), aluminum alloy (A6061-like), F-rich (Teflon-like), Cl-rich, and Ryugu particles, along with minor amounts of C, F-rich (Viton-like), C-rich (butyl and/or PEEK-like), SiO2 (quartz glass-like), and Co-bearing silicate particles. The SUS304-like, A6061-like, and Teflon-like particles correspond to materials used in the chamber and handling tools, and are considered to have originated from long-term mechanical abrasion. Many Cl-rich particles were also identified, although their origin remains unclear. The presence of Ryugu particles on the floor of the chamber is likely attributable to electrostatic scattering or accidental dropping events during handling of Ryugu samples. The Viton-like particle is likely consistent with a fragment of the Viton-coated butyl gloves used in the chamber. The SiO2 particle is likely derived from the quartz-glass lid used in the sample containers (φ10, 15 mm) and/or other dishes (e.g., φ60 mm). The Co-bearing silicate matches Co-bearing akermanite that was used during handling rehearsals prior to the return of the Ryugu samples. Hence, most of the identified particles are thought to have originated from within the clean chamber, underscoring the need to establish chamber-cleaning procedures. The information obtained in this study will contribute to improvement in curation techniques include contamination control of returned samples and environmental assessment inside the clean chambers. Moreover, these information about potential contaminant particles are of critical importance for researchers analyzing the returned samples. When unexpected materials are observed during analysis, the catalog provides essential criteria for determining whether such features are intrinsic to the parent body or are contamination introduced during terrestrial handling or from the environment. It should be noted that the potential contaminant particles provided here does not necessarily represent the particles that are typically attached to actual Ryugu samples. This is because the Ryugu particles are stored inside sealed sample containers within the clean chamber at all times except during handling or analysis, making the possibility of external contamination extremely low.

Fields of Study & Subjects

Astro and Planetary Science Spacecraft Design and Technology Electron and X-Ray Spectroscopy Techniques

Publication details

Journal / source
Institutional Repositories DataBase (IRDB)
Volume
JAXA-RM-25-004E
Publication date
18 February 2026