MATHEMATICAL MODELING OF THE OPERATION OF REGENERATIVE AIR HEATERS IN METALLURGICAL PRODUCTION BASED ON THE CFD METHOD

Read full text Summarise with VIRAT
Authors: Vadym Bezkorovainyi, А. Н. Ганжа, Олександр Вадимович Кошельнік, Natalia Marchenko
Cited by: 0
References: 4

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Regenerative air heaters for blast furnaces are considered, which are designed for high-temperature heating of large volumes of blast air due to the heat of blast furnace gas. They are structures up to 60 m high and up to 9 m in diameter. Due to the periodicity of operation of heat exchangers of this type, several devices are used for each blast furnace, combined into a block. The air heater consists of a combustion chamber and a nozzle chamber. The nozzle of the air heater is a stacked block with channels for the passage of the coolant. The nozzle is located on a sub-nozzle device made of heat-resistant cast iron. The outside of the air heater is covered with a casing made of low-alloy steel. Currently, many metallurgical plants use blast furnace air heaters with an internal combustion chamber, the main feature of which is the placement of the nozzle chamber and the combustion chamber in one housing in parallel. Also, these air heaters use a “tube-in-tube” burner, into which blast furnace gas (or a mixture of blast furnace gas with natural/coke oven gas) and fan combustion air are supplied. Purpose of work: as a result of the analysis, to assess the efficiency of the combustion chamber. An analysis of the temperature field inside the shaft and the combustion chamber masonry wall was performed based on CFD modeling for a nozzle block with a con-ical channel with a diameter of 30 mm. It was found that there is a significant non-uniformity of the fraction of the remaining combustible components at the inlet to the nozzle chamber. There is incomplete combustion when using a “pipe-in-pipe” burner and non-uniformity of the distribution of temperatures and speeds in the vertical section of the air heater along the axis of the “pipe-in-pipe” burner nozzle. The speeds at the outlet from the burner nozzle and the opposite wall area of the air heater can reach 41–43 m/s.

Fields of Study & Subjects

Iron and Steelmaking Processes Heat Transfer and Optimization Heat Transfer and Numerical Methods

Publication details

Journal / source
Integrated Technologies and Energy Saving
Issue
1
Pages
32–41
Publication date
27 March 2026
Language
EN