Assessment of atrial septal defect size during systole and diastole using 4D CT: a case series

Read full text
Authors: Yukihiro Nishimoto, T. Kawase, Ryo Fujii, Ryo Nangoya, Munehide Nagao, Kazuki Noda, Goki Inno, Kenta Nishiya, 高橋 洋介
Cited by: 0

Abstract

Background: The size of atrial septal defects (ASDs) is typically measured using echocardiography. In contrast, computed tomography (CT) images offer superior spatial resolution, and four-dimensional (4D) CT enables visualization of the defect hole during various cardiac phases. In this study, we compared the results of 4D CT measurements of defect sizes during atrial systole (As) and atrial diastole (Ad) in 7 of 18 cases of robot-assisted ASD closure (Robotic ASD closure) with measurements obtained by other methods. Case Description: , IQR 94.2) (P=0.04). Conclusions: Using 4D CT, it was possible to determine the morphology and area of ASD defects in As/Ad before surgery. This is useful for selecting surgical procedures and determining patch size and may contribute to reducing cardiac arrest and surgical time. To prove that 4D CT can accurately predict the size and morphology of the defects in As/Ad, further accumulation of cases and analyses are required.

Fields of Study & Subjects

Cardiovascular and Diving-Related Complications Congenital Heart Disease Studies Cardiac Imaging and Diagnostics

Publication details

Journal / source
AME Case Reports
Volume
10
Pages
49–49
Publication date
1 January 2026
Language
EN