Accuracy and clinical utility of near-point-of-care blood tests for predicting incident tuberculosis in exposed contacts in high burden settings: a multi-country observational cohort study

Read full text Summarise with VIRAT
Authors: Shima M. Abdulgader, Arthur Chiwaya, Marc Bañuls, Willy Ssengooba, Dinis Nguenha, James Sserubiri, Patricia Manjate, Catarina Bazima, Vinzeigh Leukes, Adam Penn‐Nicholson, Achilles Katamba, Moses L. Joloba
+3 more Alberto L. García‐Basteiro, Grant Theron, Frank G. J. Cobelens
Cited by: 0
References: 20

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Background: The scale-up of tuberculosis preventative treatment is a global health priority yet constrained by our inability to identify which exposed contacts should be prioritised. We evaluated the diagnostic accuracy and clinical utility of new and established tests, including the first deployable host mRNA assay, done near point-of-care to diagnose incident tuberculosis in contacts in Mozambique, South Africa, and Uganda Methods : Contacts microbiologically-negative for tuberculosis or without symptoms were followed for 12 months. Xpert MTB-Host Response (Xpert MTB-HR), haemoglobin, and CRP was done by a minimally trained healthcare worker at M0 and M6 using finger-prick blood. Tuberculosis disease was identified at months 0, 6 and 12 by symptom- and chest X-ray-screening (microbiological testing if symptomatic or able to expectorate sputum or CXR-positive; CXR M12 only). Predictive accuracy and decision curve analyses were done, with microbiological confirmation serving as the primary reference standard. Results: Among 3,031 contacts, 66 incident cases occurred. At a 75% sensitivity threshold (the minimum WHO-recommended sensitivity), Xpert MTB-HR and haemoglobin had specificities of 55% (95% confidence interval 53-56) and 25% (24-26), respectively. CRP’s highest sensitivity with non-zero specificity was 52% (38-65) at 71% (69-72) specificity. At 75% specificity (the minimum WHO-recommended specificity), sensitivities were 61% (48-74), 37% (25-51) and 41% (28-55), respectively. Xpert MTB-HR and CRP in parallel (either positive) had highest sensitivity [76% (62–87)] and specificity of 59% (58-61), and the best clinical benefit for a number-willing-to-treat of 20-50. Conclusion: No tests individually met WHO sensitivity and specificity criteria but Xpert MTB-HR came closest. This work resets expectations for host RNA tests. Multi-marker strategies, including personalised risk scores, should be pursued.

Fields of Study & Subjects

Tuberculosis Research and Epidemiology Infectious Diseases and Tuberculosis Diagnosis and treatment of tuberculosis

Publication details

Journal / source
Research Square
Publication date
31 March 2026
Language
EN
Document type
Preprint