Early results of Preserflo MicroShunt implantation in primary open-angle glaucoma

Read full text
Authors: A. N. Zhuravleva, S. Yu. Petrov, A. V. Starostina, O. M. Kalinina, O. M. Filippova, S. M. Kosakyan, O. I. Markelova
Cited by: 1
References: 15

Abstract

Purpose: to evaluate the efficacy and safety of Preserflo MicroShunt implantation in patients with primary open-angle glaucoma (POAG) as the first and second glaucoma surgery in the early postoperative period. Material and methods. Single-center prospective non-randomized study of Preserflo MicroShunt implantation in 12 patients (12 eyes) aged 60,4 ± 17,8 with moderate and advanced POAG with an average IOP of 30.3 ± 9.1 mm Hg. IOP was determined at 1, 3, 7 days, 2 weeks, 1 and 3 months after surgery. Results. The IOP level was 10.2 ± 5.0, 9.4 ± 4.4, 11.3 ± 4.5, 10.8 ± 4.2, 12.7 ± 5.6 and 13.0 ± 6.1 mm Hg, respectively. Baseline average visual acuity was 0.5 ± 0.3, unchanged either on day 7 or by 3 month. Hypotony £ 6 mmHg was in 4 cases, with a flat anterior chamber and choroidal effusion without Seidel positive leakage in 2 cases, without anterior chamber reformation. In 5 cases, IOP increase required bleb needling filtration, and in 2 cases — the medication therapy restart. Conclusion. Preserflo MicroShunt implantation in patients with POAG is an effective and safe procedure for up to 3 months after surgery.

Fields of Study & Subjects

Glaucoma and retinal disorders Corneal surgery and disorders Retinal and Macular Surgery

Publication details

Journal / source
Russian Ophthalmological Journal
Publisher
Real Time, Ltd.
Volume
18
Issue
4
Pages
34–38
Publication date
9 January 2026
Language