Alternative progressive stamping injection determination by eddy current sensors readings
Abstract
The study discusses the accuracy of eddy current sensors in measuring material thickness, during production process with a maximum deviation of 25,3 µm. It presents a comparison table of calibrated plates and sensor readings, highlighting certain discrepancies attributed to measurement techniques, random errors and sensor positions. The experiment's findings show that by implementing sensors it is possible to monitor process in real time and adjust parameters accordingly.
Fields of Study & Subjects
Non-Destructive Testing Techniques
Metal Forming Simulation Techniques
Advanced Machining and Optimization Techniques
Publication details
- Journal / source
- Mechatronic Systems and Materials Proceedings
- Volume
- 1
- Pages
- 17–21
- Publication date
- 9 January 2026
- Language
- EN