Evaluation of Five Large Language Models for Parental Education in Pediatric Anesthesia: Reliability and Readability Study
Abstract
Background: Although large language models (LLMs) show potential for patient education, their accuracy, usability, and comprehensibility lack validation in high-risk pediatric anesthesia. Rigorous evaluation is therefore essential prior to widespread clinical use in perioperative parental anesthesia education. Objective: This study aims to evaluate the accuracy, reliability, and readability of responses generated by 5 LLMs to parental inquiries regarding pediatric anesthesia, and to assess their suitability for clinical use in perioperative caregiver education. Methods: Two expert anesthesiologists identified 33 parental questions on pediatric anesthesia by screening authoritative resources and Google Trends. On December 14, 2025, these questions were submitted to 5 LLMs (DeepSeek-V3.2, ChatGPT-5, Gemini 2.5 Flash, Copilot, and Perplexity) via official web interfaces with default settings and zero-shot prompting, with each query in a separate conversation. Responses were standardized for blinded assessment. Two pediatric anesthesiologists with ≥10 years of clinical experience independently evaluated accuracy and reliability using the 4-point Likert accuracy scale, DISCERN, Ensuring Quality Information for Patients (EQIP), Journal of the American Medical Association (JAMA) benchmark, and Global Quality Score (GQS). After text preprocessing, readability was evaluated using 6 algorithms (Automated Readability Index [ARI], Flesch Reading Ease Score [FRES], Gunning Fog Index [GFI], Flesch-Kincaid Grade Level [FKGL], Coleman-Liau Index [CL], and the Simple Measure of Gobbledygook [SMOG]) via an online calculator. Interrater reliability was analyzed using the intraclass correlation coefficient (ICC); differences across models were assessed with the Kruskal-Wallis H test; and deviations from the sixth-grade benchmark were evaluated using 1-sample Wilcoxon signed-rank tests (P90%; P=.12), with Gemini reaching 100%. Nevertheless, safety risks and content hallucinations were still observed. Excluding Gemini and Copilot, the remaining 3 models (ChatGPT, DeepSeek, and Perplexity) each produced unsafe content in 3.03% (n=1) of the 33 queries. Hallucinations were detected in all models except Gemini, with DeepSeek and Perplexity showing the highest hallucination rate (3/33, 9.09%). Furthermore, Perplexity showed superior reliability on DISCERN (median 41; P
Fields of Study & Subjects
Health Literacy and Information Accessibility
Artificial Intelligence in Healthcare and Education
Ethics and Legal Issues in Pediatric Healthcare
Publication details
- Journal / source
- JMIR Medical Informatics
- Publisher
- JMIR Publications Inc.
- Volume
- 14
- Pages
- e93054–e93054
- Publication date
- 18 June 2026
- Language
- EN