Employing seamless mesh implants during Lichtenstein hernia repair with the use of insights enabled by artificial intelligence

Read full text Summarise with VIRAT
Authors: Andrey Dmitrievich Protasov, Mekhaeel Shehata Fakhry Mekhaeel, S.M. Salem
Cited by: 0
References: 19

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Relevance. Globally, there are now 32.53 million hernia cases, up from about 23.92 million during the previous 3 decades. Many authors lack statistical knowledge, which could jeopardize healthcare. The aim was to use artificial intelligence as a statistical technique to assess the potential effects of AdhesixTM self-gripping mesh implants, HertraTM mesh implants, and LintexTM glue-fixed mesh implants on the outcomes of inguinal hernia patients who underwent open inguinal hernia repair in Lichtenstein. Materials and Methods. We performed 120 Liechtenstein-compliant inguinal hernia repair procedures on three evenly split patient groups (n = 40) using AdhesixTM, HertraTM, and LintexTM mesh implants. The parameters for comparison were the time-frame of the procedure, hospital-stays, challenges afterwards surgery, and issues that arose during the brief follow-up. Results and Discussion. Patients of the first group were hospitalized for shorter periods of time than those in the second and third groups (group A-4.9 bed /day, group B-4.9.5 bed /day, and group C-4.95 bed /day), with no statistically significant differences. Patients in the first group experience a significantly shorter procedure time, followed by those in the second and third groups (27.8 min, 31.4 min, and 38.9 min respectively). Unlike the third group, which included 3 patients with postoperative discomfort and 1 with postoperative seroma formation, the first and second groups’ postoperative hospitalization stays were free of complications. In contrast to the third group’s 2 patients who experienced mesh migration and hernia recurrence, the first and second groups’ patients experienced no complications during the short-term follow-up. Conclusion. Compared to LintexTM mesh implants, the operative times using AdhesixTM and HertraTM are significantly shorter with no post-operative complications or hernia recurrence.

Fields of Study & Subjects

Hernia repair and management Surgical Sutures and Adhesives Aortic aneurysm repair treatments

Publication details

Journal / source
RUDN Journal of Medicine
Volume
30
Issue
1
Pages
55–65
Publication date
15 March 2026
Language
EN