Evaluation of the sensitivity of measuring circuits for corona discharges detection

Read full text
Authors: Milad Soltany, Jordi‐Roger Riba, Santiago Bogarra
Cited by: 0

Abstract

Partial discharges (PD) play a major role in the degradation of insulation in high voltage equipment. PD occurs when localized electrical breakdowns occur in the presence of a high electric field near an insulator. A critical aspect of PD measurement is the calibration of the measurement system. Calibration results in a scale factor (k), that is used to convert the measured signal to the apparent charge. This paper presents a comparative analysis of five different measurement circuits used for PD detection. The experiments were performed using a sphere-to-plane configuration. In addition to the conversion factor, this study also examines the signal-to-noise ratio (SNR) for each measurement system. Key words. Corona discharges, partial discharges, apparent charge, calibration, sensitivity.

Fields of Study & Subjects

High voltage insulation and dielectric phenomena Advanced Electrical Measurement Techniques Aerosol Filtration and Electrostatic Precipitation

Publication details

Journal / source
Renewable Energies Environment and Power Quality Journal
Volume
25
Issue
3
Pages
265–269
Publication date
1 February 2026