UTICAJ ZASIĆENJA NA INDUKTIVNOSTI SINHRONE MAŠINE SA STALNIM MAGNETIMA

Read full text
Authors: Miljana Naumov, Dejan G. Jerkan
Cited by: 0

Abstract

The paper addresses the linear magnetic model of a permanent magnet synchronous machine and highlights its shortcomings. Then, a nonlinear magnetic model is presented, where the inductances are not constant values but depend on the current, and in more detailed analyses, mutual inductances are also considered. These inductance values are obtained using the frozen permeability method, which is implemented within numerical FEA simulations. The results of the mentioned simulations are provided at the end of the paper.

Fields of Study & Subjects

Magnetic Properties and Applications Electric Motor Design and Analysis Sensorless Control of Electric Motors

Publication details

Journal / source
Zbornik radova Fakulteta tehničkih nauka u Novom Sadu
Volume
40
Issue
10
Pages
963–966
Publication date
2 January 2026