A Comparative Study of Red Cell Histogram Along with CBC Parameters and Peripheral Blood Smear in Various Anemias

Read full text Summarise with VIRAT
Authors: Preeti Sinha, Mukesh Prasad Sah
Cited by: 0
References: 19

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Background: When it comes to determining the underlying cause of anemia, the importance of microscopic examination of peripheral blood smears (PBSs) cannot be understated. The red blood cell (RBC) parameters produced by cell counters can help with morphological classification of anemia. Therefore, a thorough evaluation of anemia requires both RBC values and microscopic inspection of PBSs. The purpose of this study was to assess and contrast the outcomes of two distinct approaches: automated cell counter-generated parameters and peripheral blood smear (PBS) analysis. Finding any variations or parallels between the diagnostic results generated by each approach was the goal. Methods: From June 2025 to November 2025, a hospital based, prospective study was conducted at Department of Pathology, JLNMCH, Bhagalpur, and Bihar. Total 1000 anemic patients was evaluated and compare the PBS findings and RBC parameters and histograms generated by a cell counter. Results: In a sample of 1000 cases, we compared the typing of anemia using an automated analyzer and peripheral smear examination. Out of these cases, 690 showed consistent typing results between the two methods, while 310 showed discordant typing. The automated analyzer diagnosed majority of cases 70.1% as microcytic anemia and Normocytic, dimorphic, and macrocytic cases were found in 13.5%, 7.8%, and 4.3% of cases, respectively. Additionally, a normal histogram was observed in 17.6% of cases. Conclusion: We have concluded that while the automated analyzer is useful in reducing the overall workload through its graphical representation of anemia typing, it should always be confirmed through microscopy. The automated analyzer is a helpful tool, it should not be relied upon solely for accurate anemia typing. Microscopy remains an essential method for confirming the results of automated analysis.

Fields of Study & Subjects

Clinical Laboratory Practices and Quality Control Hematological disorders and diagnostics Iron Metabolism and Disorders

Publication details

Journal / source
International Journal of Current Pharmaceutical Review and Research
Volume
18
Issue
02
Publication date
28 February 2026
Language
EN