Abstract
The SOTS site is located on the northern edge of the SAZ, at 47°S, 142°E, southwest of Tasmania, Australia. Most of the results presented in this synthesis have been published elsewhere (Barrett et al., 2021; Bressac et al., 2019; Ellwood et al., 2020a; Grun et al., 2023; Janssen et al., 2020; Latour et al., 2023; Maharaj et al., 2025; Strzepek et al., 2025). Briefly, most seawater samples for trace metal determination were collected using acid-cleaned, Teflon-coated, externally-sprung, 12-litre Niskin bottles attached to an autonomous rosette (SeaBird) equipped with an SBE 911plus CTD unit (SeaBird). A General Oceanics autonomous rosette was used for samples collected on the 2016/17 Antarctic Circumnavigation Expedition voyage. Upon retrieval, the Niskin bottles were transferred into a clean laboratory container. Seawater samples for dissolved trace metal analysis were filtered through acid-cleaned 0.2-µm capsule filters (Supor AcroPak 200, Pall) and acidified to a final pH ≤ 1.8. Dissolved trace metal concentrations were determined by isotope dilution, Fe, Ni, Cu, Zn, Cd, and Pb or by standard addition, Mn, using an offline custom-built pre-concentration system. Briefly, weighed sample aliquots were spiked with enriched isotopes (57Fe, 61Ni, 65Cu, 67Zn, 110Cd, 206Pb) and internal standards (Sc, Y, In, Yb). Equilibrated samples were buffered to pH ≈ 6 with ammonium acetate buffer and loaded onto a column packed with Nobias Chelate PA1 resin (Sohrin et al., 2008). After removal of the seawater matrix, samples were eluted in 1 M HNO3 and analysed by inductively coupled mass spectrometry (ICP-MS) on either a Neptune or Element XR instrument (ThermoScientific). For some samples, Fe and Zn concentrations were obtained using the double-spike technique for Fe and Zn isotope determination (Ellwood et al., 2020a; Ellwood et al., 2020b). Particulate trace metal samples were collected in situ onto acid-leached 0.2-µm Supor (142 mm diameter) filters (Pall) using six large-volume dual-head pumps (McLane Research Laboratories), deployed at various water depths. For most profiles, one pump depth was used as a procedural blank, whereby only 4-8 L of water was pumped through the filter. Elemental analysis for particulate Fe, Ni, Cu, Zn, Cd, Pb, Co, Mn, Al, and P was performed on samples and referenced to a standard calibration curve. These were measured using high-resolution ICP-MS (Element XR, Thermo Scientific) in medium-resolution mode or quadrupole ICP-MS with KED (Kinetic Energy Discrimination) (iCAP Thermo Scientific). Blanks associated with collecting and processing particulate samples were routinely measured, along with in-house and external reference standards. Detailed, blank and recovery information can be found in (Barrett et al., 2021; Ellwood et al., 2020a; Grun et al., 2023; Janssen et al., 2020; Latour et al., 2023; Maharaj et al., 2025; Strzepek et al., 2025) .